Leave Your Message

UF Membrane Module 9 inch PVDF Ultrafiltration Membrane Module UFf2860 Replacing Project

Product Overview UFf2860 type capillary hollow fiber membrane is high polymer material, which will not have any phase change. Modified PVDF material adopted on this product has good permeable rate, good mechanical properties, good chemical resistance and pollution resistance. MWCO is 200K Dalton, membrane ID/OD is 0.8mm/1.3mm, filtering type is outside-in.

    Applications

    Drinking treatment of tap water, surface water, well water and river water.
    Pretreatment of RO.
    Treatment, recycle and reuse of industrial waste water.

    Filtration Performance

    This product is proven to have below filtering effects according to the service conditions of different water sources:

    Ingredient Effect
    SS, Particles > 1μm Removal Rate ≥ 99%
    SDI ≤ 3
    Bacteria, Viruses > 4 log
    Turbidity < 1NTU
    TOC Removal Rate: 0-25%

    *Above data is obtained under the condition that feeding water turbidity is < 25NTU.

    Product Parameters

    1

    Technical Parameters

    Filtering Type Outside-in
    Membrane Material Modified PVDF
    MWCO 200K Dalton
    Membrane Area 52m2
    Membrane ID/OD 0.8mm/1.3mm
    Dimensions Φ225mm* 1860mm
    Connector Size DN50 Clamping; Air Inlet – 10mm air pipe

    Application Data

    Pure Water Flux 8,000L/H (0.15MPa, 25℃)
    Designed Flux 40-120L/m2.hr (0.15MPa, 25℃)
    Suggested Working Pressure ≤ 0.2MPa
    Maximum Transmembrane Pressure 0.15MPa
    Maximum Backwashing Pressure 0.15MPa
    Air Washing Volume 0.1-0.15N m3/m2 .hr
    Air Washing Pressure ≤ 0.1MPa
    Maximum Working Temperature 45℃
    PH Range Working: 4-10; Washing: 2-12
    Operating Mode Cross Flow or Dead End

    Feeding Water Requirements

    Before feeding water, a security filter < 50 μm should be set to prevent blockage caused by large particles in raw water.

    Turbidity ≤ 25NTU
    Oil & Grease ≤ 2mg/L
    SS ≤ 20mg/L
    Total Iron ≤ 1mg/L
    Continuous Residual Chlorine ≤ 5ppm
    COD Suggested ≤ 500mg/L

    *Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.

    Operating Parameters

    Backwashing Flow Rate 100-150L/m2.hr
    Backwashing Frequency Every 30-60min.
    Backwashing Duration 30-60s
    CEB Frequency 0-4 times per day
    CEB Duration 5-10min.
    CIP Frequency Every 1-3 months
    Washing Chemicals:
    Sterilization 15ppm Sodium Hypochlorite
    Organic Pollution Washing 0.2% Sodium Hypochlorite + 0.1% Sodium Hydroxide
    Inorganic Pollution Washing 1-2% Citric Acid/0.2% Hydrochloric Acid

    Component Material

    Component Material
    Membrane Modified PVDF
    Sealing Epoxy Resins
    Housing UPVC

    description2